Table 5.

Reliability of laboratory tests in the presence of emicizumab

Laboratory testReliability of measuring emicizumab activityReliability of measuring activity of extrinsically given FVIII concentrate
aPTT Not reliable Not reliable 
FVIII activity—one stage method Not reliable—grossly overestimates hemostatic potential Not reliable 
FVIII activity—chromogenic method with bovine reagents Does not measure emicizumab Reliable method of measuring underlying intrinsic and administered FVIII activity. Unaffected by emicizumab. 
FVIII activity—chromogenic method with human reagents Linear correlation with emicizumab blood concentration and can be used as a surrogate to an emicizumab level Measures underlying intrinsic and administered FVIII activity, but emicizumab will interfere 
Emicizumab concentration Reliable method of emicizumab concentration but not readily available Does not measure FVIII activity 
Laboratory testReliability of measuring emicizumab activityReliability of measuring activity of extrinsically given FVIII concentrate
aPTT Not reliable Not reliable 
FVIII activity—one stage method Not reliable—grossly overestimates hemostatic potential Not reliable 
FVIII activity—chromogenic method with bovine reagents Does not measure emicizumab Reliable method of measuring underlying intrinsic and administered FVIII activity. Unaffected by emicizumab. 
FVIII activity—chromogenic method with human reagents Linear correlation with emicizumab blood concentration and can be used as a surrogate to an emicizumab level Measures underlying intrinsic and administered FVIII activity, but emicizumab will interfere 
Emicizumab concentration Reliable method of emicizumab concentration but not readily available Does not measure FVIII activity 
Close Modal

or Create an Account

Close Modal
Close Modal