Insertion site thrombosis rates for vena caval filters
Filter type . | IST—No surveillance . | IST—Routine surveillance . |
---|---|---|
Stainless steel Greenfield | 87/898 (9.6%) | 50/217 (23%) |
Range 1-47% | Range 14-41% | |
Titanium Greenfield | 35/267 (13.1%) | 23/82 (28%) |
Range 2-50% | Range 25-50% | |
Bird's nest | 31/417 (7.4%) | 23/101 (23%) |
Range 0-33% | Range 21-33% | |
Simon nitinol | 22/191 (11.5%) | 11/36 (31%) |
Range 0-64% | Range 16-64% | |
Vena Tech | 36/215 (16.7%) | 16/44 (36%) |
Range 8-44% | Range 34-44% |
Filter type . | IST—No surveillance . | IST—Routine surveillance . |
---|---|---|
Stainless steel Greenfield | 87/898 (9.6%) | 50/217 (23%) |
Range 1-47% | Range 14-41% | |
Titanium Greenfield | 35/267 (13.1%) | 23/82 (28%) |
Range 2-50% | Range 25-50% | |
Bird's nest | 31/417 (7.4%) | 23/101 (23%) |
Range 0-33% | Range 21-33% | |
Simon nitinol | 22/191 (11.5%) | 11/36 (31%) |
Range 0-64% | Range 16-64% | |
Vena Tech | 36/215 (16.7%) | 16/44 (36%) |
Range 8-44% | Range 34-44% |
Abbreviation: IST indicates insertion site thrombosis.