Abstract
Objective: to identify predictive factors of complications and mortality in danaparoid-treated HIT-patients.
Patients and Methods: case-control study involving HIT-patients defined by a relative decrease in platelet count of over 40% with or without thrombosis at presentation and positive laboratory testing (functional assay +/− ELISA). A patient presenting a complication 48 hours after heparin replacement with danaparoid (thrombosis, DIC, amputation, haemorrhage, death) was considered as a case.
Results: 49 cases and 65 controls were included (mean age 67±14 y; 51% women), from cardiovascular (53%) or orthopaedic (5%) surgery, intensive care (6%) or medicine (8%) units. Mean duration to complication was 7 days (D): death (n=26); thromboses (n=23); DIC (n=6); amputations (n=4); and haemorrhages (n=8).
In univaried analysis, compared to controls, cases presented:
an earlier HIT (7.9±3.5 versus 10.1±7.1 D; p=0.03)
a lower platelet nadir (53±37 versus 70±37 G/L ; p=0.01),
a more frequent thrombosis at HIT diagnosis (59% versus 32%, p=0.004),
a later heparin withdrawal after HIT diagnosis (2.8 versus 1.3 d; p=0.01),
a delayed heparin replacement (3.7 versus 1.9 d ; (p=0.001),
an inadequate dosage of replacement therapy (44% versus 19% ; p=0.004).
In multivaried analysis, predictive factors leading for poor outcome were:
an initial thrombosis at HIT diagnosis (OR=3.2 [1.3–8]),
a delay greater than 48 h for replacement therapy with danaparoid (OR=6.6 [2.5–17.3]),
insufficient doses of danaparoid (OR=4.3 [1.5–12]).
Conclusion: this study confirms the mandatory need for a prompt replacement therapy and strict adherence to recommended doses for HIT-patients.
Disclosures: No relevant conflicts of interest to declare.
Author notes
Corresponding author