Hydroxyurea (HU) is used in suppressing the bone marrow and producing fetal-like red blood cells (RBCs). These RBCs are large in size and may theoretically disturb the microcirculation. In five patients with myeloproliferative disorders (MPD), the RBC geometry and deformability were analyzed before and after 6 to 8 months of HU treatment. In untreated MPD, the RBC geometry and filterability was normal. After HU, the RBC membrane area increased 24% and the cell volume increased 39% (P < .005). This change resulted in a 12% increase in the minimum cylindrical diameter (MCD). From a static bending model of initial deformation, the RBC diametrical cross-section had a significantly increased section modulus. However, this increase in profile stiffness was compensated for by its larger projected cell area and, thus, pressure load on the RBC corpuscle. The resulting resistance to initial deformation therefore remained unchanged after HU. These findings were tested experimentally; with 3-μm filter membranes, HU treatment caused a significant increase in flow resistance (P < .02), in accordance with MCD. However, with 5-μm pores, no difference was seen, again in consonance with the theoretical findings of initial deformation. Because most capillaries are larger than 3 μm, we suggest that HU is acceptable from a perspective of cellular microrheology.

THE CIRCULATING red blood cells (RBCs) reflect the bone marrow, both cell geometrically and functionally, such as with growth hormone stimulation1 and with neonatal RBCs.2 Diseases of the bone marrow may also cause abnormal geometry of the circulating RBCs, an example being sickle cell anemia, in which the hemoglobin (Hb) is abnormal with a change in a terminal amino acid and structural defect of the protein configuration and solubility. Myeloproliferative disorders (MPD) are another group of bone marrow diseases, including polycythemia vera (PV), essential thrombocythemia (ET), and myelofibrosis (MF), with various degrees of changes in the myelopoiesis and circulating number of erythrocytes and platelets.3 When there is a need for myelosuppression, hydroxyurea (HU), a DNA synthesis inhibitor, has been increasingly used. In both sickle cell anemia4,5 and MPD,6,7HU has been found useful to modify the gene expression to produce fetal Hb (HbF).6 HU reduces the production of sickel Hb and retards the myeloproliferation, respectively. However, a side effect of HU treatment is megaloblastic change of the RBCs.8 

Although the megaloblastic effects of HU has been known for many years,8 the consequences of this RBC change on the microcirculation is still under debate. Most of this research is from sickle cell anemia,9 during which the HU changes per se are affected and partly masked by the sickle cell disease. Not much is known about the blood cell rheology in MPD and the possible effects of HU treatment on relatively normal RBCs. We addressed this problem by analyzing the geometry and filterability of RBCs on previously untreated patients with MPD before and after 6 to 8 months of HU treatment. The RBC geometry was analyzed using cell curvature profile generation with the possibility of calculating and estimating the theoretical consequences of the HU-induced RBC change. These theoretical interpretations were also tested experimentally by RBC filterability measurements using both 5-μm and 3-μm Nucleopore membranes. The 5-μm pores measure the effects on initial bending deformation, whereas the 3-μm pores are sensitive to maximum deformation close to the critical minimum cylindrical diameter (MCD) limit.

Patients and HU treatment.

Five patients with newly diagnosed MPD were selected. Four of the patients had ET, whereas one was subgrouped to have MF with thrombocytosis. All five patients were about to begin receiving chemotherapy treatment because of thrombocytosis, symptoms, and/or thrombotic/hemorrhagic complications. The inclusion in the study had no influence on the clinical routine and treatment. The patients were analyzed immediately before HU and were then observed 6 to 8 months later during ongoing HU treatment. HU was administered daily, using an oral dose of 0.5 to 1 g/d. Normal controls were healthy age-matched hospital personal, who were studied in parallel. These controls were not the same individuals before HU and at the follow-up, thus producing 5 + 5 control observations.

Blood sampling and media.

Blood samples were from venopuncture using standard heparinized 10-mL test tubes. The blood was centrifuged at 1,500g for 10 minutes with buffy coat removal. This was repeated three times to wash the RBCs, each time by topping up the suspension to 10 mL. Using this standard routine, most of the plasma, leukocytes, and platelets were removed. The final resuspension hematocrit for filtration analyses was set to 5%. The resuspending medium consisted of a Krebs-Ringer solution (135 mmol/L NaCl, 4.7 mmol/L KCl, 1.2 mmol/L KH2PO4, 1.2 mmol/L MgSO4) buffered with 20 mmol/L HEPES and supplemented with 2.56 mmol/L CaCl2, 5 mmol/L D-glucose, and 0.2 g/L human serum albumin (Fraction V Albumin; Sigma Chemical Co, St Louis, MO). The pH was set to 7.40 and the final medium had an osmolality of 299 ± 1 mOsm. Medium osmolality was measured by freezing-point depression (Osmette Osmometer; Precision Systems, Inc, Natick, MA). The medium was also prefiltered through a 0.45-μm Millipore filter (Millipore Corp, Molsheim, France).

All experimentation was conducted on two parallel blood samples, one from the MPD patient and one from the matched control. These blood samples were coded all through the study, after which time the patient identity was disclosed.

RBC geometry.

About 5 μL of the whole blood was diluted in 1 mL of RBC suspension medium and incubated for 30 minutes before analysis. A chamber for RBC geometry measurement was made from coverslips on a microscope slide to make a rectangular compartment (18 × 10 × 0.17 mm). A drop of suspended RBCs was introduced into the slit entrance of the chamber, and the openings were sealed with immersion oil. RBCs were allowed to sediment with the chamber held upside down. After 2 minutes, the chamber was turned right side up and mounted in the microscope. A large proportion of the previously settled RBCs were thus hanging vertically from the upper glass surface. On these vertical RBCs, the diametrical cross-sections were focused on using bright field illumination (Carl Zeiss ×100/1.25 oil objective lens; Carl Zeiss, Oberkochen, Germany). A digitizing table with light-spot cursor (MOP-Videoplan; Kontron Bildanalyse GmbH, Munich, Germany) was optically superimposed on the microscopic image. The RBC diameter, maximum thoroidal thickness, and central thickness were measured. A thin diffraction band surrounded the RBC cross-sections due to differences in refractive indices between the RBC and the suspending medium to which the uniform shell rule was applied during measurements.10 The method used here is consistent with that described in previous publications, to which readers are referred for further details.1,2,11 12 RBCs (50 cells per sample) were focused on one by one and measured at their diametrical cross-section, a procedure that required about 15 minutes of microscopy per blood sample.

RBC profile calculations.

The above measurements were loaded into equation 1 expressing the RBC profile curvature, originally derived from Evans and Fung13and later remodelled11,12:

Equation 1

With the aid of equation 1, the RBC membrane area and volume were computed by solving the volume integral and using numerical computer integration for membrane area calculation.11 The cell area-to-volume ratio was calculated together with the surface area index, which describes the relative excess of membrane area beyond that required to enclose the cellular volume. 2,14 MCD was then derived from the area (A) and volume (V) by a third order equation11:

Equation 2
RBC folding resistance.

It is possible to mathematically calculate the mechanical resistance to initial bending deformation of the RBC corpuscle in terms of a section modulus value. The section modulus only considers the RBC shape and size and not the membrane mechanical properties as such, eg, elastic shear, dilation, or surface bending moduli or their interrelations. The section modulus is calculated for the RBC corpuscle, consisting of a 0.01-μm–thick membrane shell model12 with linear elastic behavior.15 The unit becomes μm3.

The static bending model.

The corpuscle section modulus value is evaluated using a static bending model in which the RBC is stressed due to a pressure difference between the two sides of the cell (here set to a fictitious pressure of 1 kPa). The pressure generates a bending moment and hence a membrane tension, both having a maximum at the diametrical cross-section of the RBC12; the higher the tension, the more deformable the RBC. The tension is mathematically given by the quotient of bending moment-to-section modulus, with the unit nanoNewton/μm2 (nN/μm2). This method of theoretical analysis is useful to evaluate the influence of RBC shape and size only on corpuscle deformability.11 12 

RBC filterability.

The capillary function of RBC was studied by a filterability model on resuspended cells. This was studied by means of a specially developed filtration system.1,2 16 This system uses a digital balance (Mettler PM480; Mettler Toledo AG, Greifensee, Switzerland) in connection with a computer (IBM PS/2 Model 50; IBM UK Ltd, Greenock, Scotland) for high precision monitoring of the filtration flow. The accumulated weight is transmitted by a frequency of 7.5 Hz, with on-line calculation of flow rate versus time, and is not limited in volume. This sampling rate gives a sufficient resolution in time in relation to the obtained flow rate and the resolution of the balance, corresponding to 1 μL/0.13 seconds. All analyses were made at room temperature (22°C to 24°C).

A computer was programmed for communication with the balance for data sampling, experimental timing, calculation of statistics, and storage of filtration data. The computer program was here designed to find the peak in initial flow at filtration onset, thus avoiding artifacts associated with the acceleration of fluids.16 The filtration is driven by a constant hydrostatic pressure of 600 Pa. The filtration chamber and filter are vertically located to reduce cell sedimentation artifacts. Filterability was measured as a function of time and with respect to the initial filtration rate and clogging rate and, thus, with the possibility of detecting different measures of cellular rheology. Nucleopore polycarbonate membranes were used having pore diameters of 5 and 3 μm and a capillary length of about 11 μm (lots no. 54F8A36 and 62E0B32, respectively; Nucleopore Corp, Pleasanton, CA). In the configuration of the filtration system used, filters were cut from larger sheets (8 × 10 inches to 15-mm wide strips) and connected so that a roll of filter was made. These rolls (5 and 3 μm) were mounted on the filtrometer and allowed rapid change between each filtration. A blank filtration was used to calibrate each filtration. However, the variability in blank filtrations was negligible, because all filters were from the same batch; furthermore, within each experiment, all filters were from the same sheet. The nominal pore density was 4.0 × 105pores/cm2 and 2.0 × 106pores/cm2 for the 5-μm and 3-μm filters, respectively. The active filter area was 70.9 mm2 (open area of the filter support), which produced a total number of filterable pores of 2.84 × 105 and 1.42 × 106, respectively.

The erythrocyte filterability indices were calculated by means of a regression analysis of the flow rate, starting at the initial flow peak and during a 20-second filtration period. The filterability was expressed as RBC incremental volume (RBCiv) and clogging rate (RBCcr). The filtration rate decreased with time due to pore clogging of rigid erythrocytes and some contaminating leukocytes. The initial filtration rate (FRBC) was extrapolated from the regression line to time 0, thus reflecting the filtration rate before pore clogging. The RBC incremental volume (RBCiv) was calculated based on the initial filtration rate of blood (FRBC) and that of cell-free medium (Fm) and with correction for the RBC particle concentration (RBCc):

Equation 3

This equation expresses the relative decrease in filtration rate due to RBCs as compared with that of medium alone, Fm. The concentration of RBCs in the suspension, RBCc, is also considered. More precisely, the RBCiv (expressed as nanoliters per RBC) is the volume of medium that is hindered from passing a narrow pore due to the presence of an RBC within it.

The decrease in filtration rate is due to clogging particles (RBCcr). The clogging rate can be evaluated by relating the slope, k (filtration rate as a function of filtration time) to the initial filtration rate, FRBC:

Equation 4

Npis the average number of initially open filter pores (see above). The unit for clogging particles will be RBC per second. The calculations in the present report are, in principle, in accordance with those described by Matrai et al,17 except that the filtration rate is expressed here as a function of time instead of as a function of volume.

Statistics.

Data are presented as the mean values ± SEM. For statistical differences, both paired and unpaired t-tests were used for matched analyses with respect to differences induced by HU and for analysis versus control individuals, respectively. With unpaired testing, correction was made for unequal variance and different number of observations between groups. The different numbers of observation are indicated in the tables (n). Five levels of significance were tested; P < .051, P < .022,P < .013, P < .0054, andP < .0015.

Clinical response.

The patients were diagnosed according to required criteria for MPD. The Hb concentration varied with the MPD spectrum. One patient had supranormal Hb and an MPD profile towards PV, but with normal RBC mass and classified as ET; the Hb was reduced after HU. In another patient, the Hb was subnormal (MF) and increased during HU treatment. In the remaining three patients, an isolated ET was observed in which the Hb remained largely unaffected by HU (Table1). In all included patients, the platelet counts were increased and became successfully reduced after HU (P < .05).

The mean corpuscular Hb concentrations (MCHC) were at normal levels in all patients and remained unaffected by HU (Table 1). The mean corpuscular volume (MCV) was normal but increased markedly during HU treatment. It is noteworthy that this MCV was derived from electronic sizing, which indicated a volume increase from 89.0 ± 1.0 μm3 to 116.4 ± 4.4 μm3 (P < .01). The patients tolerated the HU treatment well, and all five patients had clinical benefits from the myelosuppression; in all patients, the symptoms or complications at diagnosis resolved or improved (Table 1).

Effects of HU on the RBC geometry.

The circulating RBCs of patients with MPD were normal in cell geometry, with close to identical cross-section profiles to those of matched normal control individuals (Table 2). After HU treatment, the RBC geometry was increased dramatically (Table 2). This was seen in both diameter and thoroidal thickness by 10.0% ± 2.0% and 15.1% ± 2.6%, respectively. The central thickness remained unchanged. The resulting cell profile was generated by computer iteration to produce a larger RBC with marked increase in both membrane area and cell volume by 24.0% ± 4.5% and 39.0% ± 6.3%, respectively. The area-to-volume ratio decreased, whereas the surface area index remained unchanged.

Effects of HU on calculated RBC deformability.

The patients with MPD had normal RBC geometry and, thus, no difference in calculated deformability indices (Table 2). However, the HU-induced change in RBC size produced highly significant alterations in these calculated RBC deformability indices. These changes were found in terms of both maximum deformation, represented by MCD, and initial bending rigidity, as judged from the static bending model. The MCD increased significantly by 11.7% ± 0.9%; furthermore, the percentage of RBC having an MCD greater than 3.5 μm increased by 263% ± 39% (Table 2). This dramatic percentage increase suggests a larger resistance to pass a narrow capillary and with more capillary blockage.

The bending section modulus that was calculated for each RBC diametrical cross section indicated a significantly more rigid RBC membrane shell profile; this increase was by 23.6% ± 1.9% (Table 2). However, although the corpuscle profile was associated with a larger calculated bending resistance, when the larger projected surface area was taken into consideration and thus the larger pressure load on the RBC to initiate deformation, the generated membrane tension was almost the same before and after HU treatment (Table 2).

Effects of HU on the measured RBC filterability.

The RBC filterability in patients with untreated MPD was not significantly different from those of normal controls. This was seen using both 3-μm and 5-μm pore filters, although there was a small tendency for a decreased filterability in MPD patients using the 5-μm filtration model (interpreted as a small increase in both RBCiv and RBCcr; Table 3). After HU treatment, a significant reduction in filterability was recorded with 3-μm filters as the RBCiv increased by 221% ± 63% (P < .02). There was also a 23% ± 13% increase in the the corresponding RBCcr, but without becoming significant. No significant changes were seen using the 5-μm pore size (Table 3).

The oxygen delivery from the blood to the surrounding tissue is promoted by the narrow dimensions of the capillaries. The RBC are folded in the capillaries because these are narrower than the cell diameter, of the order of 4 to 5 μm.18 The RBC therefore relies on its ability to deform (ie, cellular deformability), which in large part is due to the relative excess of membrane area to cell volume. RBCs of unfavorable shape and size may impair the blood flow in the macrocirculation by viscosity increase, but more obviously in the microcirculation with retarded cell passage through the capillary network. Impaired RBC deformability is thought to contribute to the sequestration of senescent cells.19 

HU has become a useful treatment to alter the gene expression of the bone marrow and thus the circulating blood cells.5,20 This is achieved by a change in the ribonucleotide reductase during the mitotic S-phase.21 Regardless of treated disease, HU produces fetal-like RBCs with HbF.22 Fetal RBCs are known to be larger in size2,14 and are similar to the cells seen with HU treatment.8 In MPD, the administration of HU is aimed at altering the concentration of circulating RBCs and platelets by suppressing the abnormal myelopoiesis in favor of the fetal gene expression.6 This is done to reduce the clinical symptoms of MPD, such as thrombotic and hemorrhagic complications.23 However, the beneficial effects of HU are paralleled by a possible disadvantage of having large-size fetal RBCs. Intuition tells us that these large cells would more easily be trapped in the microcirculation. Our aim was to analyze this phenomenon by parallel experimental and theoretical observations on MPD patients before and after HU treatment and to compare the data to normal controls.

In each patient, the cross-sectional profiles of 50 random RBCs were carefully measured by computerized image processing. From triplicate size measurements, the RBC curvature equation was computer generated, and various RBC deformability indices were calculated. These indices were calculated according to (1) a static bending model12to simulate the initial corpuscle bending deformation at capillary entrance and (2) MCD calculation to find the minimum capillary diameter the RBC can pass without lysis.11 14 The theoretical data were compared with those of experimental filtration measurements using (1) 5-μm pore membranes to simulate the initial deformation (cf, RBC static bending model) and (2) 3-μm pore membranes to analyze the final stage of deformation (cf, MCD).

The tested MPD patients had normal RBC geometry and a filterability resistance comparable to that of the matched controls. In the literature there are no absolute answers as to how the circulating blood cells are affected in MPD; this may depend on the wide spectrum of MPD diseases with dysplastic erythropoiesis and, in many cases, possible coexistence of iron deficiency24 and thus altered RBC geometry. The present patients showed normal RBC geometry, which makes the interpretation of the HU more strict. Note, our microscopy data suggest slightly oversized RBCs (in MPD patients and normal controls), with an average cell volume of 105.7 ± 3.3 μm3 and membrane area of 141.4 ± 3.0 μm2 in the control group. These recordings are about 10% larger than that recorded using micropipette aspiration of RBC (93.2 ± 1.5 μm3 and 133.3 ± 1.6 μm2, respectively).25 Similar reference values on RBC geometry are available based on microscopy interference holography,13 although larger size reference values, similar to those recorded here, also exist.26,27 Thus, the exact geometry of the average RBC is not known, and the variations in reference value depend on the used techniques. This is due in part to the optical limits with light microscopy. With the present data, the RBC geometry is derived from diametrical cross-sections. This technique requires a consistent tracing routine of a diffraction band that outlines the cell and is the result of the light resolution and the difference in refractive indices between the RBC and the surrounding medium. The RBC diffraction phenomenon was first analyzed by Ponder28 and later reevaluated by Korpman et al.10 With the Korpman rule,10 the cell membrane is thought to be found in the middle of the diffraction band, which is the guideline today. However, there is probably no exact tracing rule for the membrane edge, a fact that may account for the apparent oversizing of the normal RBC in this study. As an example of optical effects, by assuming an error on the linear scale corresponding to the light-microscopy resolution of approximately 0.2 μm, an RBC diameter of 8 μm has a potential optical error of ±2.5%. The second and third power errors, membrane area and cell volume, are 5.1% and 7.7%, respectively. This example simplifies the true calculations, because the cell diameter is only one of three measured parameters from which the RBC curvature is synthesized. The optical limits may thus introduce apparent discrepancies in baseline cell size. However, this does not affect the interpretations made in this study because of the systematic nature of the membrane-tracing routine. Note also that electronic orifice sizing of RBC (ie, Coulter counter) is affected by a shape factor correction29 and does not represent exact estimates of the RBC geometry, especially not shape-changed RBCs. In MPD with discoid RBCs, one would assume that the shape-factor error would be rather consistent to yield a good estimate of the true MCV. In this study, the Coulter counter indicated a 30.9% ± 5.3% increase in MCV due to HU, which did not differ significantly from the microscopy data (39.0% ± 6.3%). Microscopy measurements on vertical RBCs and diametrical cross-section profiles are far more time-consuming than using Coulter counting; however, the microscopy technique has been made more available due to modern computer technology and the use of a modified RBC curvature equation.12 Furthermore, with the curvature equation, not only the RBC volume is derived but also membrane area and various deformability indices based on the RBC cross-sectional profile (see below).

After HU treatment, the trombocythemia was reduced and, in most cases, normalized. From a clinical perspective, the HU treatment was successful, with no signs of disturbed microcirculation. The RBC concentration was reduced in the patient having Hb in the upper range, whereas it was increased in the patient with a clinical profile towards MF. The cell size was dramatically increased, whereas the average MCHC remained at normal level. In this study, we analyzed the start and end points before and after 6 to 8 months of HU. Our previous research has indicated a close to linear increase in MCV with time of HU treatment, until a steady-state occurred at about 5 months.30 During this initial period, two separate pools of RBC were seen: those with normal MCV and those with HU-affected geometry, respectively. This was followed by a complete replacement with HU-RBC.30Previously in the literature, the terms responders versus nonresponders have been attributed the pattern of HbF increase in HU-treated MPD patients.6 Although we did not measure HbF or detailed temporal dynamics of RBC geometry change, it is tempting to look at the different end-point RBCs as possible responders or nonresponders. All patients showed a dramatic increase in MCV, whereas the MCHC varied. However, there was no correlation between the rate of MCV increase versus MCHC change in a way that could reflect different response patterns. Further research may highlight this issue.

Our Coulter counter data in HU-treated MPD patients seem comparable to results in sickle cell anemia. However, our 131% ± 5% increase in MCV appears somewhat larger than in many sickle cell reports.31,32 This may be attributed the hemolytic anemia in sickle patients with an increase in reticulocytes and thus an increase in MCV before HU treatment. It could also reflect errors associated with the shape-factor correction of sickle RBCs in Coulter counting. In our study on MPD, the average MCHC appeared unaffected by HU; this is again paralleled by observations in HU-treated dogs and in many sickle cell studies.31 

The RBC microscopy measurements, as with the Coulter data, also showed a dramatic increase in RBC size; the cell diameter and thickness were significantly increased, whereas the central thickness (dimple) remained unchanged. The RBC curvature calculation produced a significant increase in both RBC membrane area and cell volume. These changes resulted in a significant decrease in RBC area-to-volume ratio, whereas the surface area index remained unchanged. The calculation of MCD gave a significant increase of 12%.

When the RBC cross-sectional profile of HU-treated patients was analyzed using the static bending model, a significantly larger section modulus was generated, suggesting a greater required force to initiate deformation of the corpuscle. However, the larger RBC diameter after HU also resulted in a larger projected surface area and thus deforming pressure load. This increased pressure load balanced the increase in section modulus to generate similar membrane tension and deformation in the RBC before and after HU.

The filtration analyses of HU-RBC correlated well with the theoretical observations and geometry. With 3-μm pore membranes, a significantly increased filtration resistance was produced by HU. This increase drives the attention to the increase in MCD and the percentage of RBC having an MCD larger than 3.5 μm from 17% to 59% after HU (cells that would effectively be trapped within the filter). With 5-μm pores, there were no significant differences associated with HU treatment. This lack of difference using the 5-μm filtration correlated with the theoretical findings given by the static bending model. The RBC geometry change after HU produced a more stiff corpuscle shell profile; however, this profile was balanced by a larger projected cell area and hence deforming pressure load. The resistance to initiate RBC folding thus remained larger without change after HU treatment. It is noteworthy that, with 5-μm pores, the RBC will required only minor folding to pass for which the static bending model appears relevant.

In conclusion, patients with MPD have RBCs of normal shape, geometry, and rheological function. With HU treatment, the bone marrow is suppressed to produce fetal-like large RBCs. The present detailed microscopic measurements of individual RBC cross-sectional profiles confirms this geometry change; not only is the cell volume increased, but also the membrane area. However, in addition to mere cell geometry, the calculations were extended to also analyze the mathematical deformability; an obvious impairment in micropore function (MCD increase) was seen, whereas the initial corpuscle bending deformability appeared unaffected. These calculations were confirmed by 3-μm and 5-μm filterability measurements, respectively. Because the capillaries in the circulation are larger in diameter than 3 μm,18 we suggest that the HU-induced change in RBC geometry is acceptable from a perspective of cellular microrheology.

Supported by grants from the Swedish Medical Research Council (12x-11204), the Swedish Diabetes Association, the Swedish Society of Medicine, the Medical Faculty at Umeå University, and the Sahlberg Fund.

Address reprint requests to K. Gunnar Engström, MD, PhD, Department of Cardiothoracic Surgery, Umeå University Hospital, S-901 85 Umeå, Sweden.

The publication costs of this article were defrayed in part by page charge payment. This article must therefore be hereby marked “advertisement” in accordance with 18 U.S.C. section 1734 solely to indicate this fact.

1
Engström
KG
Ohlsson
L
Oscarsson
J
Effect of hypophysectomy and growth hormone substitution on red blood cell morphology and filterability in rats.
J Lab Clin Med
116
1990
196
2
Engström
KG
Ohlsson
L
Morphology and filterability of red blood cells in neonatal and adult rats.
Pediatric Res
27
1990
220
3
Laszlo
J
Myeloproliferative disorders (MPD): Myelofibrosis, myelosclerosis, extramedullary hematopoiesis, undifferentiated MPD, and hemorrhagic thrombocytemia.
Semin Hematol
12
1975
409
4
Charache
S
Dover
GJ
Moyer
MA
Moore
JW
Hydroxyurea-induced augmentation of fetal hemoglobin production in patients with sickle cell anemia.
Blood
69
1987
109
5
Lu
ZH
Steinberg
MH
Fetal hemoglobin in sickle cells anemia: Relation to regulatory sequences cis to the beta-globin gene. Multicenter study of hydroxyurea.
Blood
87
1996
1604
6
Alter
BP
Gilbert
HS
The effects of hydroxyurea on hemoglobin F in patients with myeloproliferative syndroms.
Blood
66
1985
373
7
Löfvenberg
E
Wahlin
A
Management of polycythemia vera, essential thrombocythaemia and myelofibrosis with hydroxyurea.
Eur J Haematol
41
1988
375
8
Bergsagel
DE
Frenkel
EP
Alfrey
CP
Thurman
WG
Megaloblastic erythropoiesis induced by hydroxyurea (NSC-32065).
Cancer Chemother Rep
40
1964
15
9
Ballas
SK
Dover
GJ
Charache
S
Effect of hydroxyurea on the rheological properties of sickle erythrocytes in vivo.
Am J Hematol
32
1989
104
10
Korpman
RA
Dorrough
DC
Brailsford
JD
Bull
BS
The red cell shape as an indicator of membrane structure.
Blood Cells
3
1977
315
11
Engström
KG
Täljedal
I-B
Increased size and biconcavity in red blood cells of obese-hyperglycaemic mice.
Biorheology
25
1988
625
12
Engström
KG
Mechanics of the red blood cell corpuscle: Section modulus, shape, and stringent profile-curvature equation.
J Theor Biol
138
1989
529
13
Evans
EA
Fung
Y-C
Improved measurements of the erythrocyte geometry.
Microvasc Res
4
1972
335
14
Linderkamp
O
Meiselman
HJ
Geometry, osmotic, and membrane mechanical properties of density-separated human red cells.
Blood
59
1982
1121
15
Evans
EA
LaCelle
PL
Intrinsic material properties of the erythrocyte membrane indicated by mechanical analysis of deformation.
Blood
45
1975
29
16
Lindmark
K
Engström
KG
Analysis of flow acceleration during erythrocyte filtration: Dependence of hematocrit and cell rigidity.
Biorheology
33
1996
379
17
Matrai
A
Reid
H
Bogar
L
Flute
PT
Dormandy
JA
Initial filtration rate and initial clogging in the hemorheometre.
Biorheology
22
1985
275
18
Canham
PB
Potter
RF
Woo
D
Geometric accommodation between the dimensions of erythrocytes and the calibre of heart and muscle capillaries in the rat.
J Physiol
347
1984
697
19
LaCelle
PL
Arkin
B
Acquired rigidity: A possible determinant of normal RBC life span.
Blood
36
1970
837
20
Adunyah
SE
Chander
R
Barner
VK
Cooper
RS
Regulation of c-junction mRNA expression by hydroxyurea in human K562 cells during erythroid differentiation.
Biochem Biophys Acta
1263
1995
123
21
Young
CW
Schichetman
G
Karnofsky
DA
Hydroxyurea-induced inhibition of deoxyribonucleotide synthesis: Studies in intact cells.
Cancer Res
27
1967
526
22
Burns
ER
Reed
LJ
Wenz
B
Volumetric erythrocyte macrocytosis induced by hydroxyurea.
Am J Clin Pathol
85
1986
337
23
Sagripanit
A
Ferretti
A
Nicolini
A
Carpi
A
Thrombotic and hemorrhagic complications in chronic myeloproliferative disorders.
Biomed Pharmacother
50
1996
376
24
Gilbert HS, Stump DD, Roth EF: Hydroxyurea-associated reduction of red cell deformability. Clin Res 33:546A, 1985
25
Engström
KG
Meiselman
HJ
Effects of pressure on red blood cell geometry during micropipette aspiration.
Cytometry
23
1996
22
26
Canham
PB
Difference in geometry of young and old human erythrocytes explained by a filtering mechanism.
Circ Res
25
1969
39
27
Nash
GB
Wyard
SJ
Changes in surface area and volume measured by micropipette aspiration for erythrocytes ageing in vivo.
Biorheology
17
1980
479
28
Ponder
E
The measurement of the diameter of erythrocytes. V.-The relation of the diameter to the thickness.
Quart J Exp Physiol
20
1930
29
29
Waterman
CS
Atkinson
EE
Wilkins
B
Fischer
CL
Kinzey
SL
Improved measurement of erythrocyte volume distribution by aperture-counter signal analyses.
Clin Chem
21
1975
120
30
Löfvenberg
E
Nilsson
T
Wahlin
A
Jacobsson
L
Hydroxyurea treatment of myeloproliferative disorders. Macro-megaloblastic blood and bone marrow changes.
Acta Med Scand
222
1987
169
31
Orringer
EP
Blythe
DSB
Johnson
AE
Phillips
G
Dover
GJ
Parker
JC
Effects of hydroxyurea on hemoglobin F and water content in the red blood cells of dogs and of patients with sickle cell anemia.
Blood
78
1991
212
32
Bridges
KR
Barabino
GD
Brugnara
C
Cho
MR
Christoph
GW
Dover
G
Ewenstein
BM
Golan
DE
Guttmann
CRG
Hofrichter
J
Mulkern
RV
Zhang
B
Eaton
WA
A multiparameter analysis of sickle erythrocytes in patients undergoing hydroxyurea therapy.
Blood
88
1996
4701
Sign in via your Institution