We are pleased that our work raised the interest of the scientific community. Indeed, the main aim of the paper was to characterize the pattern of alternative splicing of the factor XI (F11) gene and to study its role in the regulation of F11 expression by the coupling of nonproductive splicing and nonsense-mediated mRNA decay.

In their letter, Gailani and coworkers focused their efforts in providing evidence against the existence of a factor XI (FXI) protein isoform in plasma originating from the skipping of exons 6 and 7 and therefore lacking the C-terminal half of the A2 domain and the N-terminal half of the A3 domain (FXI-Δ6/7). The rationale of their strategy was to show that the FXI-Δ6/7 is not recognized by monoclonal antibodies against A2 and A3 domains, whereas these same antibodies readily react against an approximately 105-kDa band immunoprecipitable from both human plasma and media conditioned by cells expressing full-length recombinant FXI. However, Gailani and colleagues' position is based on the assumption that the 105-kDa band corresponds to the hypothetical Δ6/7 band we found in human plasma. This is unlikely to be true for the following reasons: (1) The 105-kDa band was easily detectable by Coomassie staining loading just 2 to 4 μg of FXI. Conversely, we could detect the putative Δ6/7 FXI isoform by Coomassie-stained gels only loading at least 10 μg of commercial FXI, or by Western blotting after FXI immunoprecipitation from 1.5 mL of human plasma. (2) At variance with Gailani et al, we cannot see a 105-kDa band (or any band of a similar molecular weight) when expressing recombinant full-length FXI in eukaryotic cells. The same result was found in other papers in the literature.1,2  Moreover, also in the data presented by Gailani et al, this band is undetectable in lysates of FXI-expressing HEK293 cells (compare panels C and E of Figure 1 in Gailani et al). (3) When immunoprecipitating FXI from human plasma with a mouse monoclonal antibody, we detected a band (under nonreducing conditions) migrating below FXI that was shown, by mass-spectrometry analysis, to correspond to contaminating mouse IgGs (data not shown in Asselta et al3 ). (4) The matching between the 105-kDa species and the putative Δ6/7 FXI isoform is further hampered when considering that more than one band is detectable in nonreducing SDS-PAGE of plasma FXI purified by affinity chromatography with goat anti–human FXI polyclonal antibody (our unpublished data). Mass spectrometry of these additional excisable bands demonstrated that they correspond to contaminating proteins (ie, ceruloplasmin, complement factor H, haptoglobin, and serum albumin).

In conclusion, we agree that our data do not unequivocally demonstrate the existence of a circulating FXI isoform originating from the Δ6/7 FXI transcript (as thoughtfully stated in our original paper3 ). However, we feel that the results presented by Gailani and colleagues are still not conclusive. A future possibility could be to purify enough FXI from human plasma to be able to analyze fast-migrating FXI-specific bands by mass spectrometry after digestion with a protease (such as Glu-C) generating Δ6/7-specific peptides.

R.A. and V.R. contributed equally to this work.

Contribution: R.A., V.R., and I.G. wrote the first draft, G.S. revised the manuscript, and S.D. critically reviewed the final version of the letter. All authors contributed to compare their results with those presented in the Gailani letter and to the critical rethinking of their original data.

Conflict-of-interest disclosure: The authors declare no competing financial interests.

Correspondence: Prof Stefano Duga, Department of Biology and Genetics for Medical Sciences, University of Milan, Via Viotti, 3/5-20133 Milano, Italy; e-mail: stefano.duga@unimi.it.

1
Zucker
 
M
Zivelin
 
A
Landau
 
M
et al. 
Characterization of seven novel mutations causing factor XI deficiency.
Haematologica
2007
, vol. 
92
 
10
(pg. 
1375
-
1380
)
2
Zivelin
 
A
Ogawa
 
T
Bulvik
 
S
et al. 
Severe factor XI deficiency caused by a Gly555 to Glu mutation (factor XI-Glu555): a cross-reactive material positive variant defective in factor IX activation.
J Thromb Haemost
2004
, vol. 
2
 
10
(pg. 
1782
-
1789
)
3
Asselta
 
R
Rimoldi
 
V
Guella
 
I
et al. 
Molecular characterization of in-frame and out-of-frame alternative splicings in coagulation factor XI pre-mRNA.
Blood
2010
, vol. 
115
 
10
(pg. 
2065
-
2072
)
Sign in via your Institution