Abstract
Introduction
Umbilical cord blood collections are typically performed using one of two methods: the syringe collection method and the gravity collection bag method. Collection volume, total nucleated cell (TNC) count, total CD34 positive cell count and percent with microbial contamination were analyzed to determine differences between collections performed using these two methods.
Methods
Units were processed using a hydroxyethyl starch red blood cell depletion method. TNC counts were measured using a Beckman Coulter HmX Analyzer. Total CD34 positive cell counts and viability were measured using the Beckman Coulter Epics XL-MCL flow cytometer. Microbial testing was performed using the VersaTrek system. Data related to collection volume and cellular content were analyzed by a Wilcoxin rank sum test of the paired differences [95% confidence interval (CI) for the difference between the control and experimental (syringe collections) results].
Results and Conclusions
The total cord blood volume collected via the syringe method was not significantly lower than that collected using the gravity collection bag method. However, the TNC count and total CD34 positive cell count from syringe collections were significantly inferior to the TNC count and CD34 positive cell count from gravity bag collections. The rate of microbial contamination of units collected in syringes was 3.3-fold higher than that of units collected using gravity collection bags. Cord blood banks should train collection sites on optimal collection methods and monitor the compliance of all collection sites with standardized collection procedures.
. | Gravity Bag Collections . | Syringe Collections . |
---|---|---|
Collection Volume | ||
N | 27,121 | 55 |
Mean | 66 mL | 60 mL |
Standard Deviation | +/− 30 mL | +/− 24 mL |
Wilcoxin rank sum test (p-value) | 0.0945 | |
TNC Count (Post Processing) | ||
N | 27,121 | 55 |
Mean | 7.5 x 10^8 | 5.0 x 10^8 |
Standard Deviation | +/− 4.6 x 10^8 | +/− 3.5 x 10^8 |
Wilcoxin rank sum test (p-value) | <0.0001 | |
Total CD 34 Positive Cells (Post Processing) | ||
N | 20,495 | 51 |
Mean | 2.76 x 10^6 | 1.77 x 10^6 |
Standard Deviation | +/− 2.87 x 10^6 | +/− 1.32 x 10^6 |
Wilcoxin rank sum test (p-value) | < 0.0001 | |
Microbial Contamination Rate | 7.1 % | 23.6% |
. | Gravity Bag Collections . | Syringe Collections . |
---|---|---|
Collection Volume | ||
N | 27,121 | 55 |
Mean | 66 mL | 60 mL |
Standard Deviation | +/− 30 mL | +/− 24 mL |
Wilcoxin rank sum test (p-value) | 0.0945 | |
TNC Count (Post Processing) | ||
N | 27,121 | 55 |
Mean | 7.5 x 10^8 | 5.0 x 10^8 |
Standard Deviation | +/− 4.6 x 10^8 | +/− 3.5 x 10^8 |
Wilcoxin rank sum test (p-value) | <0.0001 | |
Total CD 34 Positive Cells (Post Processing) | ||
N | 20,495 | 51 |
Mean | 2.76 x 10^6 | 1.77 x 10^6 |
Standard Deviation | +/− 2.87 x 10^6 | +/− 1.32 x 10^6 |
Wilcoxin rank sum test (p-value) | < 0.0001 | |
Microbial Contamination Rate | 7.1 % | 23.6% |
Author notes
Corresponding author