Introduction

Umbilical cord blood collections are typically performed using one of two methods: the syringe collection method and the gravity collection bag method. Collection volume, total nucleated cell (TNC) count, total CD34 positive cell count and percent with microbial contamination were analyzed to determine differences between collections performed using these two methods.

Methods

Units were processed using a hydroxyethyl starch red blood cell depletion method. TNC counts were measured using a Beckman Coulter HmX Analyzer. Total CD34 positive cell counts and viability were measured using the Beckman Coulter Epics XL-MCL flow cytometer. Microbial testing was performed using the VersaTrek system. Data related to collection volume and cellular content were analyzed by a Wilcoxin rank sum test of the paired differences [95% confidence interval (CI) for the difference between the control and experimental (syringe collections) results].

Results and Conclusions

The total cord blood volume collected via the syringe method was not significantly lower than that collected using the gravity collection bag method. However, the TNC count and total CD34 positive cell count from syringe collections were significantly inferior to the TNC count and CD34 positive cell count from gravity bag collections. The rate of microbial contamination of units collected in syringes was 3.3-fold higher than that of units collected using gravity collection bags. Cord blood banks should train collection sites on optimal collection methods and monitor the compliance of all collection sites with standardized collection procedures.

Summary of Results

Gravity Bag CollectionsSyringe Collections
Collection Volume 
27,121 55 
Mean 66 mL 60 mL 
Standard Deviation +/− 30 mL +/− 24 mL 
Wilcoxin rank sum test (p-value) 0.0945  
TNC Count (Post Processing) 
27,121 55 
Mean 7.5 x 10^8 5.0 x 10^8 
Standard Deviation +/− 4.6 x 10^8 +/− 3.5 x 10^8 
Wilcoxin rank sum test (p-value) <0.0001  
Total CD 34 Positive Cells (Post Processing) 
20,495 51 
Mean 2.76 x 10^6 1.77 x 10^6 
Standard Deviation +/− 2.87 x 10^6 +/− 1.32 x 10^6 
Wilcoxin rank sum test (p-value) < 0.0001  
Microbial Contamination Rate 7.1 % 23.6% 
Gravity Bag CollectionsSyringe Collections
Collection Volume 
27,121 55 
Mean 66 mL 60 mL 
Standard Deviation +/− 30 mL +/− 24 mL 
Wilcoxin rank sum test (p-value) 0.0945  
TNC Count (Post Processing) 
27,121 55 
Mean 7.5 x 10^8 5.0 x 10^8 
Standard Deviation +/− 4.6 x 10^8 +/− 3.5 x 10^8 
Wilcoxin rank sum test (p-value) <0.0001  
Total CD 34 Positive Cells (Post Processing) 
20,495 51 
Mean 2.76 x 10^6 1.77 x 10^6 
Standard Deviation +/− 2.87 x 10^6 +/− 1.32 x 10^6 
Wilcoxin rank sum test (p-value) < 0.0001  
Microbial Contamination Rate 7.1 % 23.6% 

Author notes

Corresponding author

Sign in via your Institution