Abstract
Four platelet compatibility assays were performed on serum and platelet or lymphocyte samples from 38 closely HLA-matched donor/recipient pairs involved in 55 single-donor platelet transfusions. The 22 patients studied were refractory to transfusions of pooled random-donor platelets. Of the four assays (platelet suspension immunofluorescence, PSIFT; 51Cr release; microlymphocytotoxicity; and a monoclonal anti-IgG assay, MAIA), the MAIA was most predictive of platelet transfusion outcome (predictability, 74% for one-hour posttransfusion platelet recovery and 76% for 24-hour recovery). The only other assay to reach statistical significance was the PSIFT (63% predictability for one-hour posttransfusion recovery). The degree of HLA compatibility between donor and recipient (exact matches v those utilizing cross-reactive associations) was unrelated to the ability of the MAIA to predict transfusion results. The MAIA may be capable of differentiating HLA antibodies, ABO antibodies, and platelet-specific antibodies responsible for failure of HLA-matched and selectively mismatched single-donor platelet transfusions.